| Journal of General Virology |
| SUMMARY | INTRODUCTION | AFM TECHNOLOGY | IMAGES | CONCLUSIONS | REFERENCES |
| First posted online 1 June 2001 | REVIEW ARTICLE |
| DOI: 10.1099/vir.0.17690-0 |
Yu. G. Kuznetsov, A. J. Malkin, R. W. Lucas, M. Plomp and A. McPherson
University of California, Irvine,
Department of Molecular Biology and Biochemistry, Room 560, Steinhaus
Hall, Irvine, CA 92697-3900, USA
Atomic force microscopy (AFM) has been used to image a variety of virus particles in vitro and could, conceivably, be used as a useful diagnostic for their presence, their structural characterization and even their identification. Virus particles can be imaged by AFM in air, under alcohol or in physiological medium, and accurate measurements of their dimensions obtained. In addition, the appearance and organization of capsomere structures on their surfaces are frequently visible. A number of viruses and virus crystals have been imaged successfully using AFM and improvements in AFM technology and sample handling will undoubtedly increase even more its power, resolution and scope.
Introduction |
Two techniques that have proven particularly useful
for elucidating the detailed structures of viruses have been electron
microscopy (EM) and X-ray crystallography. These techniques have led to
our current descriptions of icosahedral and helical viruses and the
delineation of capsomere arrangements and protein subunit distributions on
their surfaces (Horne & Wildy, 1961
; Caspar & Klug, 1962
). For this, EM relied principally on heavy metal staining
or shadowing of virus particles dried in a vacuum (Finch & Holmes,
1967
; Horne & Wildy, 1963
). More recently, however, cryogenic EM has
permitted more detailed analysis of virus particles and, in many cases,
even their interior architecture in a more nearly physiological state is
visible (Baker et al., 1999
). On the other hand, X-ray diffraction has yielded
beautifully detailed models of virus particles, though generally lacking
in nucleic acid structure, at near atomic resolution (Harrison, 1990
). The major drawback of X-ray diffraction is
that the virus must be obtained in a crystalline or some other highly
ordered form suitable for analysis (McPherson, 1998
).
It is unlikely that any probe technology such as scanning transmission electron microscopy or atomic force microscopy (AFM) can, at this time, compete with cryogenic EM or X-ray crystallography as a means of delineating virus structure, particularly the interior structure. Nonetheless, AFM may have its place in accurately determining the dimensions of virus particles, their mechanical properties and the architecture of their surfaces. In the best of cases, it may be capable of revealing capsomere arrangements and perhaps even the distribution of capsid protein subunits within the capsomeres. With future improvements in AFM technology, images may begin to overlap with those of X-ray crystallography.
AFM was invented by G. Binnig in 1982 (Binnig
et al., 1986
) and has been used in
the visualization of biological structure for about the last ten years.
Its great advantages over other imaging methods are that it can be carried
out in a fluid environment, including physiological medium, and that it does
not disturb the specimen from its natural state. Furthermore, it spans a
range of dimensions from a nanometre up to a hundred micron, which is
only marginally accessible by other techniques.
AFM technology |
Fig. 1 is a schematic diagram of an atomic force microscope for imaging in fluids. The principles that define it are rather simple, surprisingly so given its acuity, but the instrument depends on associated advanced technologies for its application. In practice, an exceedingly sharp probe is brought into atomic contact with the surface of the sample object, in vacuum, air or liquid, and it is then scanned in a systematic manner over the surface of the object. The stylus, similar to a very sharp phonograph needle with a tip radius of about 5 to 40 nm, extends from the end of a short cantilever, typically 100 to 250 µm in length. To minimize the force between the tip and sample in 'contact' mode, the cantilever has a low spring constant of less than 1 N/m.
Fig. 1. A schematic diagram
of an atomic force microscope used for imaging viruses in liquids. AFM
fluid cells, sealed by O rings, are probed by a silicon nitride,
ultra-sharp stylus, which moves in a raster manner over the surface of
specified objects. A reflected laser beam amplifies and reports
deflections of the stylus, attached to a cantilever, to a split
photodiode.
Scanning using contact mode is accomplished by translating the stylus, which is under piezoelectric control, along a series of raster lines. As the probe tip moves over the surface, it interacts through aggregate atomic forces with topological features on the surface. As a consequence of these interactions, the probe is deflected. Cantilever displacements are amplified by corresponding deflections of a laser beam reflected into a split photodiode from the upper surface of the probe. Photoelectric circuitry then converts the deflections into height information. The resulting data, recorded as a digital image, can then be presented in a number of different visual formats.
AFM may be operated in either 'height' mode or 'deflection' mode. In height mode, the sample surface is maintained at a constant distance from the tip of the probe by the piezoelectric positioner below by a feedback mechanism. The cantilever deflection in this case is very small, tending to zero. In deflection mode, the sample is stationary and cantilever deflection data are collected directly.
Microfabricated cantilevers exert a force on the substrate surface and, as one might anticipate, the resolution of the technique depends on the degree of force employed. The greater the force between the probe and the surface, the more sensitive the probe is to surface variations. On the other hand, the greater the force, the more the probe will disturb the surface. Sample damage thus becomes an issue.
Problems arising in imaging in contact mode from
unfavourable probesurface interactions, particularly lateral force,
have been overcome to some extent by the development of what are known as
tapping mode instruments (Hansma et al., 1994
). In 'tapping' mode, the probe tip is not in continuous
contact with the surface (referred to as contact mode), but oscillates
rapidly up and down as it is scanned over the surface, essentially
tapping its way gently, as with a blind man's cane, but firmly and
rapidly, and sensing the height of features it encounters.
In tapping mode, the feedback mechanism adjusts, through the piezoelectric positioner, the vertical height of the sample surface in order to keep the amplitude of the freely oscillating probe constant. Tapping mode minimizes the contact between the cantilever tip and the sample surface and it greatly reduces lateral forces. As with contact mode, cantilevers made of silicon nitride, which have a low spring constant, are used for tapping mode operation in liquids. For some specimens, it is preferable to examine virus samples dried in air. For tapping mode imaging of air-dried samples, a stiffer cantilever made of silicon is used, which has a high spring constant of about 50 N/m.
This tapping mode approach has proven to be a significant blessing to biological researchers, as it has allowed the characterization of samples that would otherwise be too soft or too fragile to withstand contact mode examination. Operating in a liquid environment presents some complications due to fluid dynamics, but these are not severe. A constraint that sometimes presents obstacles is that the specimen under study must be fixed to, or made to adhere firmly to, the substrate surface of the fluid cell, which may be glass, cleaved mica, plastic or any other hard material. To achieve this, it may be necessary to treat the substrate with various reagents in order to induce better adhesion of samples. If this condition is not met, the specimen will move due to interaction with the probe and no useful information will be gathered.
AFM can be applied to scan fields ranging in size
from less than 20 nm up to about 150 µm and with a spatial resolution
on soft biological materials, in the best of cases, of about 2 to 3 nm,
with a height resolution as great as 0.5 nm. Its application extends over
the range lying between individual macromolecules, which are accessible by
X-ray crystallography, macromolecular assemblies, amenable to EM, and
living cells, which can be seen using light microscopy (Allen et
al., 1997
; Bustamante & Keller, 1995
). Because visualization is carried out in a
fluid environment, specimens suffer no dehydration, as is generally the
case with EM, and they require no fixing or staining. Indeed, specimens
can be observed over long periods as long as they stay relatively
immobilized. For the most part, specimens seem to be oblivious to the
presence of the probe tip.
The measurement of particle size and the dimensions of features of individual particles must be treated with some care. Lateral sizes of individual particles adsorbed onto mica appear considerably larger than might be expected because the image obtained is the convolution of the AFM tip shape with that of the particle. That is, the tip is not infinitely sharp and it has finite width. Thus, the curved surface immediately adjacent to the absolute tip causes vertical displacement of the cantilever and, therefore, gives rise to edges in the image before, as well as after, the absolute tip encounters the object. This does not, however, affect the total vertical displacement of the cantilever. As a consequence, single objects visualized by AFM appear broader than their true dimensions but yield an accurate and precise vertical dimension. For roughly spherical particles, such as icosahedral viruses, although their diameter appears greater than is in fact the case, the vertical height of the particles gives a remarkably accurate value for their true diameter.
Many viruses with dimensions ranging from 17 to 150 nm whose capsid sizes were accurately established by EM, light scattering or X-ray crystallography have now been examined. Images of these particles consistently showed them to have lateral dimensions of about 2.5 times their actual diameter, which serves as a reasonable rule of thumb. In all cases, however, heights measured by AFM were accurate to within a few per cent. Therefore, precise free particle diameters must be based on vertical measurements.
In the case of virus particle crystals, the situation
is different. With virus crystals, each particle is embedded in a lattice
composed of similar members. As the AFM tip passes over the surface, the
tip never approaches the 'bottom' of a single virion (i.e. a surface
equivalent to the flat mica substrate) before it encounters a neighbouring
virion. Thus, the height of the particle in crystalline form does not give
a valid measure of its true diameter. However, it is a simple matter to
measure the centre-to-centre distances of the virus particles in the
lattice and, because the virions are, in general, closely packed, these
distances do yield precise diameters of better than a few per cent.
Fourier transformation of the lattice arrays (Kuznetsov et al.,
1997
) can improve these
values.
More distinct images of virus particles can generally be obtained from virus crystals, rather than from single, free particles adsorbed onto mica or glass. This is not due to any averaging process or Fourier filtering, but seems to be an inherent property of the technique. Presumably, the immobilization of particles and their physical stability is responsible for the quality of the crystal's images. When crystals cannot be obtained, slowly drying the virus particles onto the mica substrate may induce them to form aggregates and clusters, often ordered into closely packed, two-dimensional paracrystals. These sometimes serve nearly as well as crystals. In these semi-ordered arrays, the centre-to-centre distance of particles also provides a reasonably accurate estimate of diameters.
Examples of AFM images of viruses |
Fig. 2 (a) is an
image obtained when the smallest of the spherical viruses, satellite
tobacco mosaic virus (STMV), is simply adsorbed onto fresh cleaved mica
and imaged in the fluid cell under buffer. The field is filled with more
or less spherical particles, each of 17 nm diameter based on height
measurements. These correlate exactly to those known from X-ray
diffraction analysis (Larson et al., 1998
; Ban et al., 1995
) and quasi-elastic light scattering studies (Malkin et
al., 1993
). In Fig.
2 (b), swollen STMV virions are visualized in cubic STMV
crystals and, in Fig. 2 (c), normal particles in
the orthorhombic crystal lattice (Koszelak et al., 1989
) can be seen. In both of these lattices,
individual virus particles are readily discriminated and a hexagonal
outline, characteristic of icosahedrons in projection, is evident.
Centre-to-centre distances of particles in the two lattices are 18 and 17
nm, respectively, in agreement with data from X-ray crystallography. Fig. 2 (d) is a high-magnification AFM image of
STMV in the orthorhombic lattice. While some suggestions of substructure
are evident on the 17 nm particle surfaces, no recognizable detail of the
icosahedral architecture is present.
Fig. 2. (a) STMV from
solution has been adsorbed onto mica and visualized as a field of 17 nm
diameter particles. (b) Surface of a cubic STMV crystal. (c,
d) Small areas on the surface of an orthorhombic STMV crystal,
where only the barest indications of capsid substructure are
visible.
A T=3 plant virus, brome mosaic virus (BMV),
is seen in Fig. 3 (a, b) as
individual virus particles adsorbed onto mica (Bancroft & Horne,
1977
). Virions adhere well to the substrate and are
stable to repeated scanning. The measured heights, and therefore the
diameters of the BMV virions, are 28 nm, consistent with data from X-ray
crystallography (Lucas et al., 2001
), but the lateral diameter in the AFM images is about 70
nm, or about 2.5 times the correct value. Even on free virus particles,
substructure is evident and capsomeres consisting of either five or six
protein capsid subunits can be seen. Further inspection indicates the
presence of a depression or hole at the centres of the capsomeres. BMV
particles incorporated into the lattice of an orthorhombic form of their
crystals can be seen in Fig. 3 (c). Here,
the 28 nm centre-to-centre distances agree with height estimates and with
data from other techniques. The capsomeres on the virion surfaces are
again well-resolved and the depressions at their centres
visible.
Fig. 3. (a, b)
BMV adsorbed onto a freshly cleaved mica substrate under buffer.
Capsomeres are evident on the surfaces of free particles. (c) AFM
of BMV crystals permits the visualization of capsid structure. Capsomeres
and even depressions at their centres are evident, reflecting the toroidal
clusters of coat protein subunits. (d) T=1 icosahedral
particles of 17 to 18 nm diameter, derived after CaCl2
treatment of native T=3 BMV, can be crystallized and visualized by
AFM. Even on these very small particles, pentameric capsomeres derived
from the native T=3 virus are recognizable on the T=1
surface.
If BMV native particles of T=3 are exposed to
CaCl2, they dissociate into capsid protein. The protein can
then, upon removal of the CaCl2, be induced to reassociate into
T=1 empty capsids (Yamazaki & Kaesberg, 1963
; Zhao et al., 1995
; Cuillel et al., 1981
). Fig. 3 (d) is an AFM image of
the surface lattice of their tetragonal crystals (Lucas et al.,
2001
). Heights and inter-particle
distances are in agreement with the 18 to 19 nm diameters deduced from
X-ray crystallography. Unlike STMV, large, pentameric capsomeres on
T=3 BMV protrude from the surfaces of the smaller T=1
particles (Fig. 3 ac).
Fig. 4 shows a small area
on the surface of a turnip yellow mosaic virus (TYMV) crystal (Malkin
et al., 1999
; Hirth & Givord,
1988
). Groups of six
crystallographically related T=3 particles of 28 nm diameter gather
around large, open channels with widths that are roughly equal to a virion
diameter, presumably filled with solvent. Even at this resolution, each of
the virions appears as a roughly spherical 'cluster of grapes'. In many
cases, individual grapes or substructures in the clusters can be seen to
exhibit hexagonal or pentagonal outlines characteristic of icosahedral
capsomeres. The capsomeres are well-resolved from one another on the top
surfaces of the virions and have dimensions consistent with those obtained
from X-ray crystallography, about 5 to 6 nm (Canady et al., 1996
).
Fig. 4. TYMV
particles embedded in the surface of a virus crystal exhibit an
icosahedral array of capsomeres; at high magnification, some even present pentagonal and
hexagonal shapes.
Comparison of the capsomeres of TYMV and the overall architecture of the virion with that of BMV, also T=3 but from another virus family (Tymovirus versus Bromovirus), shows them to be strikingly different. Whereas the capsomeres for BMV are wide and have crown-like structures with depressions at their centres, those for TYMV are closed and dense. Hence, it is possible, using AFM, to discriminate the two virus families on the basis of capsid structure.
Fig. 5 (a) shows a
larger, spherical plant virus, cauliflower mosaic virus (CaMV), adsorbed
onto mica. Height measurements suggest its diameter to be 48 nm, though
its width in the AFM images is about 100 nm. X-ray crystallography
indicates it to be 52 nm (Gong et al., 1990
). With AFM, even at a relatively low magnification,
quilting on the virion surface suggests the emergence of substructure. At
higher magnifications, the underlying architecture begins to develop and
individual, large capsomeric units become visible on the virion surface
(Fig. 5 bd). These have
centre-to-centre distances of 10 to 12 nm and are organized into hexameric
patterns.
Fig. 5. (a, b)
Individual virions of CaMV on a mica substrate. Even at this
magnification, some capsid substructure is seen. (c, d) At
higher magnification, the capsomeres on the virus surface are
apparent.
As virus particles become larger, their properties become more mechanically fragile. Particles are more easily distorted from
spherical form and, in some cases, breakage or rupture of the particles is
seen. AFM may be useful in assessing the damage caused by various
procedures. As seen in Fig. 6 (a), DNA can
be seen leaking from CaMV virions and spreading onto the substrate. In Fig. 6 (b), long strands of RNA still wrapped with
subunits of protein can be seen extending from the ends of tobacco mosaic
virus (TMV). In addition, it is evident that most TMV particles in sample
preparations are less than full-length and therefore unlikely to be
infectious. In Fig. 6 (c), circular RNA
molecules originating from ruptured virions of Moloney murine leukaemia
virus (MoMLV) can be seen (Lowey, 1985
).
Fig. 6. (a) Damaged
virions of CaMV are adsorbed onto cleaved mica in physiological media.
Loops of double-stranded DNA can be seen emerging, spreading onto the
substrate from most of the particles. (b) TMV helices are seen
unravelling at one or both ends and loops of single-stranded RNA complete
with protein subunits are seen displayed on the mica. (c) Degraded
virions of MoMLV are seen to release closed circular strands of RNA onto
the mica substrate.
The largest virus to be investigated by AFM is the
insect virus tipula iridescent virus (TIV). It is known from EM to have a
diameter of about 120 nm and a complicated capsid architecture enveloped
by a membrane (Williams, 1998
). If the virus is dried from water onto mica, it forms
regular hexagonal arrays that have some degree of crystalline order. An
array of air-dried TIV is shown in Fig. 7.
Though not properly crystalline, the constraints introduced by association
into an array make it possible to measure centre-to-centre distances that
agree well with height measurements and dimensions determined by other
methods. Although the capsid structure is not clear on these dried
virions, probably because of the membranes, the virus particles do exhibit
distinctive polygonal forms with large triangular faces.
Fig. 7. When virus particles
are clustered into two-dimensional arrays on the mica substrate, they are
more firmly immobilized and, therefore, yield better AFM images. The
hexagonal arrangement seen here is of the insect virus TIV. Although
little capsid structure is visible, the polygonal architecture of the
capsid is evident.
Herpesvirus is an enveloped virus of about 100 nm
with a lipoprotein membrane surrounding a protein capsid (Kaper, 1975
;
Roizman & Batterson, 1985
; Wagner & Hewlett, 1999 a
, b
). Enveloped viruses
adsorb well to a mica surface, but the protein capsid substructure is
veiled by the membrane and obscured. If the membrane is removed by
detergent, the protein capsids frequently fail to adhere. In Fig. 8 (a), the protein capsid can be seen
through the membrane of an enveloped herpesvirus virion. Despite the
membrane, some substructure does emerge beneath the shroud as ordered
units on the capsid surface. Herpesvirus treated with detergent and dried
onto a mica substrate is seen in Fig. 8 (b).
Here, the capsid structure is clearly evident and even depressions are
visible at the centres of some capsomeres.
Fig. 8. (a) A
herpesvirus particle adsorbed onto freshly cleaved mica. The virus is
still enveloped and rough indications of substructure on the surface of
the capsid are detected by the AFM probe through the lipid membrane.
(b) A herpesvirus virion treated with detergent to reveal the
underlying polygonal capsid. The virion is damaged and flattened somewhat
on the substrate, yielding a good surface for AFM imaging. Capsomeres are
clearly evident, as are axes of pentagonal and hexagonal symmetry.
Depressions at the centres of some capsomeres are also visible in some
cases.
Viruses do not need to be icosahedral to be studied
by AFM. The classic rod-shaped TMV is, for example, seen in Fig. 9.
Infectious virions are known from EM and X-ray diffraction (Bloomer &
Butler, 1986
) to have lengths of about 300 nm,
cylindrical diameters of 18 nm and a helical pitch of 23 nm. Many of the
virus particles in Fig. 9 are not full-length, but are fragments of TMV.
At the same time, anomalously long TMV particles, several times the normal
length, can also be seen in abundance, including some particles in Fig. 9.
Height measurements of these segments consistently give a value of 18 nm,
which corresponds well to the known cylindrical diameter. Apparent widths
in the AFM images, however, are again about 2.5 times that value, or about
45 nm. The repeat along the helical axis cannot be resolved unambiguously with AFM, though there are fleeting and suggestive periodicities in some
images.
Fig. 9. (a) A mass of rod-shaped TMV
virions adsorbed onto mica. (b, c) Some representative
cylindrical particles seen at higher magnification. Most are not full
virions, but are sections broken from the helical virus. (c) The 2.3
nm repeat is barely discernible on the middle virion.
Some preliminary conclusions |
AFM provides a useful approach for evaluating the dimensions, general architecture, capsomere arrangement and, in some cases, even the detailed capsid structure of viruses. Because it can be applied under physiological conditions, it captures the particles in a natural state without the distortions imposed by drying, fixing or staining. Even on individual, isolated virus particles, in the best of cases, capsomere structure can be resolved and underlying motifs identified. At this time, the method does not allow delineation of the protein subunit distribution within the capsomeres. Images suggest that viruses can be better visualized when restrained as a member of an ordered array, e.g. a crystal, but some advantage is gained even when the particles are only members of semi-ordered masses, e.g. a two-dimensional aggregate or a paracrystalline array.
Heights of single particles on mica and centre-to-centre distances of particles in ordered arrays are the most reliable measures of a virion's dimensions. If these are used, shapes and dimensions obtained by AFM agree well, to within a few per cent, with results based on X-ray structure determination. The size of the virus particle does not appear to be a limitation in terms of resolving capsid detail. That is, 17 nm virus capsids, as seen here for BMV T=1 particles, and 28 nm viruses, such as TYMV, yield as much detail as 50 or 100 nm viruses. The favourable increase in virion curvature with increase in diameter is probably compensated for negatively by increasing virion deformity. Even membrane-encapsidated virions yield some information regarding the core or protein capsid substructure.
Unrelated T=3 plant viruses, such as TYMV and
BMV, can be discriminated from one another on the basis of shape, size and
capsomere structure, even with current technology. Resolution of very
closely related viruses, such as cowpea chlorotic mottle virus and BMV,
would probably not be possible at this time. Nonetheless, AFM can give
some useful information regarding the presence or distribution of
different viruses in a sample. As AFM technology progresses and better,
more acute tips are developed (Woolley et al., 2000
), the technique will become increasingly
powerful and may begin to challenge and supplement low-resolution X-ray
crystallography.
The authors wish to thank Professor Edward Wagner for samples of herpesvirus, Professor Hung Fan for Moloney murine leukaemia virus samples and Professor Brian Federici for tipula iridescent virus. This research was supported by grants from the NIH and contracts from NASA.
References |
Bustamante, C. & Keller, D. (1995). Scanning force microscopy in biology. Physics Today 48, 3238.
Horne, R. W. & Wildy, P. (1961). Symmetry in virus architecture. Virology 15, 348373.
Wagner, E. K. & Hewlett, M. D. (1999 a). Basic Virology, pp. 337358. London: Blackwell Science.
Wagner, E. K. & Hewlett, M. D. (1999 b). Basic Virology, p. 127. London: Blackwell Science.
© 2001 SGM
This article is now available in the September 2001 print issue of JGV (vol. 82, 20252034). The complete issue of the journal may be seen in electronic form on JGV Online.